commun:jeedom_saint-jeoire
Table des matières
Domotique Jeedom à Saint-Jeoire
Home Energy Meter Gen5
Configuration des rapports.
- Byte 1 (msb):
- Bit 7: Reserved
- Bit 6: Reserved
- Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Clamp 3)
- Bit 4: Auto Send Meter Report (for kVar) at the group time interval (Clamp 2)
- Bit 3: Auto Send Meter Report (for kVar) at the group time interval (Clamp 1)
- Bit 2: Auto Send Meter Report (for KVah) at the group time interval (Clamp 3)
- Bit 1: Auto Send Meter Report (for KVah) at the group time interval (Clamp 2)
- Bit 0: Auto Send Meter Report (for KVah) at the group time interval (Clamp 1)
- Byte 2:
- Bit 7: Reserved
- Bit 6: Reserved
- Bit 5: Auto Send Meter Report (for A) at the group time interval (Clamp 3)
- Bit 4: Auto Send Meter Report (for A) at the group time interval (Clamp 2)
- Bit 3: Auto Send Meter Report (for A) at the group time interval (Clamp 1)
- Bit 2: Auto Send Meter Report (for V) at the group time interval (Clamp 3)
- Bit 1: Auto Send Meter Report (for V) at the group time interval (Clamp 2)
- Bit 0: Auto Send Meter Report (for V) at the group time interval (Clamp 1)
- Byte 3:
- Bit 7: Reserved
- Bit 6: Reserved
- Bit 5: Auto Send Meter Report (for kWh) at the group time interval (Clamp 3)
- Bit 4: Auto Send Meter Report (for kWh) at the group time interval (Clamp 2)
- Bit 3: Auto Send Meter Report (for kWh) at the group time interval (Clamp 1)
- Bit 2: Auto Send Meter Report (for Watt) at the group time interval (Clamp 3)
- Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Clamp 2)
- Bit 0: Auto Send Meter Report (for Watt) at the group time interval (Clamp 1)
- Byte 4 (lsb):
- Bit 7: Reserved
- Bit 6: Reserved
- Bit 5: Auto Send Meter Report (for kVar) at the group time interval (Whole HEM)
- Bit 4: Auto Send Meter Report (for KVah) at the group time interval (Whole HEM)
- Bit 3: Auto Send Meter Report (for A) at the group time interval (Whole HEM)
- Bit 2: Auto Send Meter Report (for V) at the group time interval (Whole HEM)
- Bit 1: Auto Send Meter Report (for Watt) at the group time interval (Whole HEM)
- Bit 0: Auto Send Meter Report (for kWh) at the group time interval (Whole HEM)
Groupe 1
2^1+2^2+2^3 = 14
Groupe 2
2^0 = 1
Groupe 3
Popp mold detector
Pour que ce module fonctionne, il faut faire des modifs dans jeedom.
Etape 1
dans le fichier html/plugins/openzwave/resources/openzwaved/config/manufacturer_specific.xml, il faut rajouter une ligne.
<Manufacturer id="0154" name="Popp"> ... <Product type="0004" id="0014" name="701202 Mold Detector" config="popp/701202.xml" /> </Manufacturer>
Etape 2
Il faut copier 701202.zip ici : html/plugins/openzwave/resources/openzwaved/config/popp/701202.xml
Etape 3
commun/jeedom_saint-jeoire.txt · Dernière modification : de francois